m³/h -20%
TILAK BHUSAL / ENGINEERING TOOLS
Pump & fan
affinity laws.
Change the speed. Explore the curve. Understand the savings.
THE ENGINEERING BEHIND THE NUMBERS
One ratio. Three relationships.
Q₂ = Q₁ × r
At constant diameter, flow at a corresponding point varies directly with rotational speed.
H₂ = H₁ × r²
Head or pressure scales with the square of speed at constant fluid density.
P₂ = P₁ × r³
At similar efficiency, shaft power follows the cube of speed. Electrical input also includes motor and drive losses.
Model assumptions, diameter rules & references
The baseline curve is H(Q) = H₀ − aQ², with a = (H₀ − H₁)/Q₁². The system curve is Hstatic + KQ², with K = (H₁ − Hstatic)/Q₁². Their proposed intersection is calculated analytically and checked with an independent numerical solver. These idealized curves cannot represent unstable or non-monotonic fan behavior.
Speed changes use 1/2/3 exponents. Same-casing pump trims approximately use 1/2/3. Geometrically similar machines use diameter exponents 3/2/5. Density stays constant. Manufacturer curves govern actual operation; custom calibration is only as reliable as its supporting measurements.
Operating shaft power is estimated as scaled shaft power × (operating flow / scaled flow) × (operating head / scaled head). This assumes constant local hydraulic efficiency. The savings estimate covers a single duty for the entered hours; actual savings need a duty profile and measured efficiencies.
References: Wilo affinity laws · Hydraulic Institute pump FAQs · AMCA fan engineering.